Hydraulic Pump Cavitation and Suction Problems

A pump cannot pull oil; atmospheric pressure has to push it in. When the inlet pressure falls too far, dissolved air comes out of the oil and the bubbles collapse inside the pump. That is cavitation, and it erodes the pump.

Published:

Revised:

How cavitation damages a pump

Danfoss notes that mineral hydraulic oil can hold up to 9% dissolved air by volume at atmospheric pressure. When pressure drops quickly, the air comes out as bubbles; when those bubbles reach high pressure they collapse, eroding the adjacent material. The more air in the oil and the greater the inlet vacuum, the worse the erosion.

Rexroth also warns that continuous operation above rated speed shortens service life because of cavitation erosion.

Inlet pressure limits

Pump makers specify a minimum pressure at the suction port. For the A10VSO piston pump, Rexroth gives 0.8 bar absolute, which must not be undercut in operation or during cold start. For the PGH gear pump, Rexroth gives 0.8–2 bar absolute, and 0.6 bar briefly at start-up.

As a conversion, 0.8 bar absolute is roughly 0.2 bar below atmosphere, about 6 inHg of vacuum. A vacuum gauge at the pump inlet is the direct way to check it; Muncie Power Products recommends this test in its pump troubleshooting guide.

Suction line sizing

Rexroth’s PGH data sheet sizes suction pipes for an oil velocity of 1–1.5 m/s. From the continuity equation, d = √(4Q / (π·v)): at 20 L/min this gives an inner diameter of about 20.6 mm at 1.0 m/s and 16.8 mm at 1.5 m/s; at 16 L/min, about 18.4 mm and 15.0 mm. This is a method example only; use the pump’s own data sheet for real designs.

Danfoss adds that denser fluids need a larger suction line or an elevated tank to keep positive inlet pressure.

Filters, oil level and reservoir layout

Rexroth installation guidance

  • Use return-line or pressure filters where possible; use suction filters only with a low-pressure switch or contamination indicator
  • Suction and return lines must end clearly below the oil level, far enough apart that return oil is not drawn straight back in
  • If suction lines are too short or the oil level too low, air is drawn in by a swirl
  • For the A10VSO: suction height at most 800 mm, immersion at least 200 mm, at least 100 mm from the tank bottom, and a baffle between suction and drain lines
  • Install suction pipework air-tight; the pump must receive air-free, calmed and cooled oil

Cold oil and other checks

Thick oil raises inlet losses. Rexroth limits cold start of the A10VSO to 1600 mm²/s, and Eaton lists vacuum, oil too thick and cold weather among causes of pump noise.

Muncie’s corrections for excessive inlet vacuum include a larger inlet hose, re-routing the hose, and checking for a kinked or collapsed hose or a clogged breather or strainer.

References

Figures above come from the following public documents. Inlet limits differ by pump; use the data sheet of the pump fitted.

Sources

  • Bosch Rexroth, Axial piston variable pump A10VSO series 31, data sheet RE 92711, pp. 4, 6–7, 43
  • Bosch Rexroth, Internal gear pump PGH series 2X, data sheet RE 10223, pp. 4, 14–15
  • Danfoss, Hydraulic Fluids and Lubricants, Technical Information 520L0463, pp. 8, 10
  • Muncie Power Products, Clutch Pump Troubleshooting Guide, TR-G03-02
  • Eaton (Vickers), PVE19 User Manual, Troubleshooting, Table 3

FAQ

Frequently asked questions

What is the difference between cavitation and aeration?

Both put bubbles in the pump. In cavitation, inlet pressure is so low that dissolved air comes out of the oil. In aeration, outside air is drawn in, usually through leaking suction fittings or a vortex at low oil level. The checks overlap: inlet vacuum, suction seals and oil level.

Is a suction strainer a problem?

It adds inlet loss, and more as it clogs. Rexroth prefers return or pressure filters and allows suction filters only with a low-pressure switch or contamination indicator.

How do I measure inlet conditions?

Fit a vacuum or absolute pressure gauge at the pump suction port and compare readings at normal speed and cold start with the pump’s data sheet limit.

ENERGY INTO VALUE

Less idle running. More value.

Make each holding phase count. Stop the motor after motion, then recharge when pressure reaches the set threshold, reducing energy use and heat from continuous idle running.

Save 75% or more in short-motion, long-hold applications. Turn reduced electricity use into lower running costs and get more value from every clamping cycle.

Annual electricity cost savingkWh avoided × electricity tariff
Review the savings potential of your machine →