Hydraulic Pipe Size and Flow Velocity Calculator

Enter flow and pipe inside diameter to get flow velocity, plus the inside diameters that give 1.0 and 1.5 m/s. Use it to check suction lines, where too high a velocity lowers inlet pressure and can cause cavitation.

Published:

Revised:

Hydraulic pipe size and flow velocity calculator

v = Q / (6 × A). Rexroth recommends 1–1.5 m/s for the suction line of its PGH internal gear pump; check the data sheet of the pump fitted.
Flow velocity
1.06 m/s
Inside diameter for 1.0 m/s
20.6 mm
Inside diameter for 1.5 m/s
16.82 mm
Send these values to an engineer

Formula

Velocity v [m/s] = Q [l/min] / (6 × A [cm²]), with A = π × d² / 400 for an inside diameter d in mm. Rearranged, d = √(400 × Q / (6 × π × v)).

Example: 20 l/min at 1.0 m/s needs an inside diameter of about 20.6 mm; at 1.5 m/s about 16.8 mm.

Suction line velocity

Rexroth’s PGH internal gear pump data sheet says to select pipe clear width for a suction speed of 1 to 1.5 m/s. This is a recommendation for that pump; check the inlet limits in the data sheet of the pump fitted.

Pressure and return line velocities are not given here because no manufacturer value has been verified for this page. The calculator works for any line; use the limits of your own design rules.

References

The suction velocity range comes from the following data sheet.

Sources

  • Bosch Rexroth, Internal gear pump PGH series 2X, data sheet RE 10223, p. 14

FAQ

Frequently asked questions

Why does suction velocity matter?

Higher velocity means higher pressure loss in the suction line, so the pump inlet sees lower pressure and is more likely to cavitate.

Is nominal pipe size the same as inside diameter?

No. Use the actual inside diameter of the tube or hose, which depends on wall thickness.

How do I convert l/min to m³/s?

Divide by 60,000. 20 l/min = 3.33 × 10⁻⁴ m³/s.

ENERGY INTO VALUE

Less idle running. More value.

Make each holding phase count. Stop the motor after motion, then recharge when pressure reaches the set threshold, reducing energy use and heat from continuous idle running.

Save 75% or more in short-motion, long-hold applications. Turn reduced electricity use into lower running costs and get more value from every clamping cycle.

Annual electricity cost savingkWh avoided × electricity tariff
Review the savings potential of your machine →