Hydraulic Power Unit Overheating: Causes and Checks

Hot oil is a symptom, not a fault in itself. Every watt the pump delivers that does no useful work ends up as heat in the oil. Find where that power is lost before adding a bigger cooler.

Published:

Revised:

What temperature is too hot?

Danfoss recommends keeping hydraulic fluid between 30 °C and 60 °C under normal operating conditions. Component makers also publish hard limits, but those are limits, not targets.

Heat shortens oil life. As a rule of thumb from Danfoss, raising fluid temperature from 80 °C to 90 °C may cut fluid life by about 50%. High temperature also oxidises the oil and shortens seal life.

Hot oil is also thinner oil. Bosch Rexroth gives an optimum operating viscosity of 16–36 mm²/s for its A10VSO pump, and a minimum of 10 mm²/s. HLP 32 oil reaches 10 mm²/s at about 73 °C; HLP 46 at about 85 °C. Thin oil leaks more internally, which creates more heat.

Where the heat comes from

Power lost across a relief or throttling valve equals pressure × flow, and all of it turns into heat. In a textbook example (NPTEL, IIT Madras), 40 L/min dumped across a relief valve at 70 bar is about 4.67 kW of heat.

This is why a fixed pump that keeps running while a clamp only holds pressure can heat the oil continuously: the flow the clamp does not need goes over the relief valve.

Common causes to check

  • Pump flow dumped over the relief valve during holding or standby
  • Internal leakage in worn pumps, valves or cylinders, which turns pressure into heat
  • Air in the oil, usually drawn in through loose suction-line seals or fittings; Danfoss notes it raises temperature and noise
  • Oil viscosity grade unsuited to the operating temperature
  • Reservoir too small for the pump flow; a course rule of thumb sizes it at 3–4 times pump flow per minute
  • Blocked air path around the reservoir or cooler, or a hot installation location

A step-by-step check

Measure before changing parts. Log oil temperature, pressure and motor running time over a representative shift, including holding and standby periods.

Then compare the pump running time with the time the machine actually needs flow. If the pump runs at full flow while the circuit only holds pressure, the relief valve is the first place to look. If heat rises with wear over months, check internal leakage. Noise and foam point to air on the suction side.

Reduce heat at the source

A cooler removes heat after it is made. Removing the wasted flow avoids making it. Options include unloading the pump during holds, variable-displacement or servo supply, or an accumulator that holds pressure while the pump stops.

Shanchuan SC-QT units use the last approach: a standard motor, pump, PLC and accumulator. The pump stops during a pressure hold and restarts when pressure falls below the set level. Whether this suits a machine depends on hold time and leakage; compare options on the same duty cycle.

References

Figures above are taken from the following public technical documents. Limits for your system come from the data sheets of the components actually fitted.

Sources

  • Danfoss, Hydraulic Fluids and Lubricants, Technical Information 520L0463, pp. 10, 15, 17
  • Bosch Rexroth, Axial piston variable pump A10VSO series 31, data sheet RE 92711, pp. 4–5
  • NPTEL (IIT Madras) course 112106175, Lectures 30–31: Accessories used in fluid power systems, self-evaluation solutions

FAQ

Frequently asked questions

Is 70 °C oil temperature acceptable?

It is above the 30–60 °C range Danfoss recommends for normal operation, and HLP 32 oil approaches Rexroth’s 10 mm²/s minimum viscosity near 73 °C. Check the limits of your actual pump and seals, and find the source of the heat.

Will a larger cooler fix overheating?

It can lower the temperature, but it does not remove the wasted power. If flow is dumped over a relief valve, that energy is still paid for. Address the loss first, then size cooling for what remains.

Why does the oil get hotter as the unit ages?

Wear increases internal leakage, and leakage turns pressure into heat. Rising temperature over months at the same duty is a reason to check pump and valve condition.

ENERGY INTO VALUE

Less idle running. More value.

Make each holding phase count. Stop the motor after motion, then recharge when pressure reaches the set threshold, reducing energy use and heat from continuous idle running.

Save 75% or more in short-motion, long-hold applications. Turn reduced electricity use into lower running costs and get more value from every clamping cycle.

Annual electricity cost savingkWh avoided × electricity tariff
Review the savings potential of your machine →