Formula
Power lost across a relief or throttle valve P [kW] = Δp [bar] × Q [l/min] / 600. All of it becomes heat in the oil.
Textbook check (NPTEL, IIT Madras): 40 l/min dumped across a relief valve at 70 bar is 70 × 40 / 600 ≈ 4.67 kW.
Why holding duties heat the oil
When a fixed pump keeps running while a clamp only holds pressure, the flow the clamp does not need goes over the relief valve. With example values of 45 bar and 16 l/min, that is 1.2 kW of heat for as long as the hold lasts.
Shanchuan SC-QT units stop the pump while pressure is held and restart it when pressure falls below the set level. Actual consumption for a given machine is verified by measurement under the same duty.
References
The formula check uses the following course material.
Sources
- NPTEL (IIT Madras) course 112106175, Lectures 30–31: Accessories used in fluid power systems, self-evaluation solutions, Q3
FAQ
Frequently asked questions
Does a variable pump avoid this loss?
A pressure-compensated variable pump reduces flow at set pressure, so much less flow crosses the relief valve; some loss from leakage and standby remains.
How do I measure the flow over the relief valve?
Install a flow meter in the relief valve’s tank line, or estimate it as pump flow minus the flow consumers take.
Is the result the same as electrical input?
No. Electrical input is higher because motor and pump losses are added; the result is the hydraulic power lost at the valve.