KNOWLEDGE / 2026.11.09

Relief Valve Heat Load Calculator

Enter the pressure drop across the valve, the flow passing over it and how many hours a day the system runs this way. The calculator returns the heat load in kW and the electrical energy turned into heat each day.

Published:

Revised:

Relief valve heat load calculator

P = Δp × Q / 600. All power lost across a relief or throttle valve heats the oil.
Heat load
1.2 kW
Energy turned into heat per day
9.6 kWh
Send these values to an engineer

Formula

Power lost across a relief or throttle valve P [kW] = Δp [bar] × Q [l/min] / 600. All of it becomes heat in the oil.

Textbook check (NPTEL, IIT Madras): 40 l/min dumped across a relief valve at 70 bar is 70 × 40 / 600 ≈ 4.67 kW.

Why holding duties heat the oil

When a fixed pump keeps running while a clamp only holds pressure, the flow the clamp does not need goes over the relief valve. With example values of 45 bar and 16 l/min, that is 1.2 kW of heat for as long as the hold lasts.

Shanchuan SC-QT units stop the pump while pressure is held and restart it when pressure falls below the set level. Actual consumption for a given machine is verified by measurement under the same duty.

References

The formula check uses the following course material.

Sources

  • NPTEL (IIT Madras) course 112106175, Lectures 30–31: Accessories used in fluid power systems, self-evaluation solutions, Q3

FAQ

Frequently asked questions

Does a variable pump avoid this loss?

A pressure-compensated variable pump reduces flow at set pressure, so much less flow crosses the relief valve; some loss from leakage and standby remains.

How do I measure the flow over the relief valve?

Install a flow meter in the relief valve’s tank line, or estimate it as pump flow minus the flow consumers take.

Is the result the same as electrical input?

No. Electrical input is higher because motor and pump losses are added; the result is the hydraulic power lost at the valve.

ENERGY INTO VALUE

Less idle running. More value.

Make each holding phase count. Stop the motor after motion, then recharge when pressure reaches the set threshold, reducing energy use and heat from continuous idle running.

Save 75% or more in short-motion, long-hold applications. Turn reduced electricity use into lower running costs and get more value from every clamping cycle.

Annual electricity cost savingkWh avoided × electricity tariff
Review the savings potential of your machine →