How an accumulator stores pressure
Oil is practically incompressible, so it cannot store pressure energy on its own. A bladder or piston accumulator stores energy by compressing nitrogen, separated from the oil.
When the pump raises system pressure, oil enters the accumulator and compresses the gas. When pressure falls, the gas pushes oil back into the circuit. In a holding circuit this covers leakage until the pressure drops to the restart level.
Setting the precharge
Precharge is the gas pressure with no oil in the accumulator. It must sit below the minimum working pressure, or the accumulator will empty before the circuit reaches it.
Published precharge rules
- HYDAC bladder accumulators: precharge p0 ≤ 0.9 × minimum working pressure p1, and maximum pressure p2 ≤ 4 × p0
- Parker bladder accumulators: precharge 90% of minimum system pressure
- Parker piston accumulators: usually 100 psi below minimum pressure (90% when minimum pressure is below 1000 psi)
- Use absolute pressures in sizing calculations
Sizing basics
Start from the oil volume the accumulator must deliver between maximum and minimum pressure, called Vw. For slow pressure-holding cycles, gas behaviour is usually treated as close to isothermal, so Boyle’s law (p × V = constant) gives a first estimate. Fast discharge is closer to adiabatic and needs a larger accumulator.
Parker’s catalogue formula for an auxiliary power source is V1 = Vw × (P3/P1)^(1/f) / [0.95 × (1 − (P3/P2)^(1/n))], where P1 is precharge, P2 maximum and P3 minimum pressure (absolute), and f and n are gas constants read from its charts. With f = n = 1 it reduces to the isothermal case.
For a clamp, Vw is the leakage volume over one holding interval, plus any oil the clamps need during the cycle. Leakage depends on the actual cylinders and valves, so measure it rather than assume it.
Temperature changes the precharge
Gas pressure rises with temperature and falls when it cools. Parker’s example: to have 1000 psi precharge at a 130 °F operating temperature when charging at 70 °F, charge to about 900 psi. Check precharge at a known temperature and correct for it.
Safety and inspection
Charge accumulators with nitrogen only; HYDAC specifies at least class 4.0 and warns that other gases risk explosion. Work on accumulators should be done by trained staff.
Accumulators are pressure vessels. In the EU, a gas vessel over 1 L falls under the Pressure Equipment Directive when pressure × volume exceeds 25 bar·L for group 1 fluids or 50 bar·L for group 2 fluids such as nitrogen. Other markets have their own rules; confirm the certificate needed for the destination country.
HYDAC’s charging-unit manual advises checking precharge after installation or repair, again within the first week, then after 3–4 months if no loss is found, and at least once a year after that.
References
Rules above come from the following public documents. Follow the manual of the accumulator actually fitted.
Sources
- HYDAC, Bladder Accumulators – Standard design, brochure EN 3.201.31/04.21, §1.1, §2.1.8–2.1.12
- Parker Hannifin, Hydraulic Accumulators, Catalog HY10-1630/US, Sizing and Selection, pp. 130–133
- HYDAC, FPO 210 Series charging and gauging unit, user manual, p. 2
- Directive 2014/68/EU (Pressure Equipment Directive), Article 4
- NPTEL (IIT Madras) course 112106175, Accumulators, self-evaluation solutions
FAQ
Frequently asked questions
What happens if precharge is too low?
The accumulator stores less usable oil between maximum and minimum pressure, so the pump restarts more often during a hold. If holding time gets shorter over time, check whether precharge has been lost.
What happens if precharge is too high?
If precharge is above the minimum working pressure, the accumulator is already empty before the circuit reaches that pressure and delivers no oil in that range.
Can I use compressed air instead of nitrogen?
No. Manufacturers specify nitrogen only. HYDAC warns that other gases risk explosion.