Hydraulic Accumulator Volume and Hold Time Calculator

Enter accumulator volume, gas precharge, the pump-on and pump-off pressures and the circuit leakage. The calculator returns the usable oil volume and the hold time with the pump stopped, using the isothermal curve Römheld applies to slow leakage.

Published:

Revised:

Accumulator usable volume and hold time calculator

Enter gauge pressures; the calculation uses absolute pressure (gauge + 1 bar). Isothermal curve, as Römheld uses for slow leakage.
Usable volume (isothermal)
53.53 cm³
Hold time (isothermal)
10.71 s
Send these values to an engineer

Formulas

Isothermal (Boyle): ΔV = p0 × V0 × (1/p_on − 1/p_off), with absolute pressures.

Hold time t = ΔV ÷ leakage rate. Römheld notes that leakage discharge is slow, so the isothermal curve can be assumed; charging is fast and close to adiabatic.

Worked example (Römheld)

750 cm³ accumulator, 100 bar precharge, pump off at 200 bar and on at 175 bar, leakage about 5 cm³/s. Römheld reads ΔV = 55 cm³ from its isothermal curve, giving 11 s.

The formula gives about 53.6 cm³ (10.7 s) with gauge pressures and 53.5 cm³ with absolute pressures; this calculator uses absolute.

Precharge limits

Limits depend on the accumulator type. HYDAC bladder accumulators: p0 ≤ 0.9 × minimum operating pressure and maximum pressure ≤ 4 × p0. Römheld gives p1 ≥ 1.1 × p0 and p2 ≤ 8 × p0 for its diaphragm accumulators. The calculator warns when the HYDAC bladder limits are exceeded.

Shanchuan SC-QT units stop the pump during a hold and restart it when pressure falls below the set level, so this calculation applies to them; actual hold time depends on the accumulator, switch settings and measured leakage of each machine, and no fixed hold time is claimed.

References

Formulas and example are taken from the following documents.

Sources

  • Römheld, Hydraulic Accumulators, data sheet F 9.601, Issue 9-22 E, pp. 2–3
  • HYDAC, Bladder Accumulators – Standard design, brochure EN 3.201.31/04.21, §2.1.9

FAQ

Frequently asked questions

Why use absolute pressure?

Boyle’s law applies to absolute gas pressure. At clamping pressures the difference from gauge is small, but at low pressure it matters.

Where do I get the leakage rate?

From the data sheets of the valves, rotary couplings and cylinders fitted, or by measuring the pressure drop of the isolated circuit over time.

Why only the isothermal curve?

Leakage empties the accumulator slowly, so Römheld uses the isothermal curve. Fast charge and discharge cycles need a polytropic method, such as Parker’s sizing formula with gas constants from its charts.

ENERGY INTO VALUE

Less idle running. More value.

Make each holding phase count. Stop the motor after motion, then recharge when pressure reaches the set threshold, reducing energy use and heat from continuous idle running.

Save 75% or more in short-motion, long-hold applications. Turn reduced electricity use into lower running costs and get more value from every clamping cycle.

Annual electricity cost savingkWh avoided × electricity tariff
Review the savings potential of your machine →