Fixture Clamping Pressure-Hold Time: How to Calculate It

With the pump stopped, a clamping circuit holds pressure only as long as stored oil can replace what leaks away. Hold time is therefore usable volume divided by leakage rate, and both can be estimated before the fixture is built.

Published:

Revised:

Why pressure switches and accumulators are used

Römheld notes that in power workholding most pressure generators run in a cycling mode controlled by a pressure switch. Devices with internal leakage, such as spool valves or rotary couplings, make the motor switch on and off often; a small accumulator considerably reduces the number of switching cycles.

Parker describes the same circuit: the accumulator maintains pressure at the clamp cylinder by supplying oil to make up for leakage, and the pressure switch setting sets the range within which the pump and motor work.

Without an accumulator, hold time is very short

Oil is stiff. Danfoss gives a bulk modulus of about 15,000 bar for mineral oil at 140 bar and 22 °C. The volume that must leak to drop pressure is ΔV = V × Δp / E. For 1 L of trapped oil and a 5 bar drop, that is only about 0.33 cm³. These are illustrative values; bulk modulus is lower at lower pressure, at higher temperature and with entrained air.

Usable volume between switch points

For slow discharge through leakage, Römheld says the isothermal curve can be assumed. With Boyle’s law, the oil an accumulator delivers between the pump-off pressure p_off and the pump-on pressure p_on is ΔV = p0 × V0 × (1/p_on − 1/p_off), where p0 is the gas precharge and V0 the nominal volume. Use absolute pressures.

Precharge limits vary by type. Römheld gives p1 ≥ 1.1 × p0 and p2 ≤ 8 × p0 for its diaphragm accumulators, with less for some types; HYDAC bladder accumulators use p0 ≤ 0.9 × p1 and p2 ≤ 4 × p0.

Hold time = usable volume ÷ leakage rate

Römheld’s worked example: a 750 cm³ accumulator with 100 bar precharge, pump switching off at 200 bar and on at 175 bar, and a maximum leakage of about 5 cm³/s. It reads ΔV = 55 cm³ from the isothermal curve, giving a switching time of 55 ÷ 5 = 11 s.

The formula gives the same result: 100 × 750 × (1/175 − 1/200) ≈ 53.6 cm³, or about 10.7 s. As a comparison under an adiabatic assumption (κ = 1.4), usable volume falls to about 45.7 cm³, or about 9.1 s. In this example, fast discharge delivers less oil than slow discharge.

Where the leakage comes from

Leakage is the number that decides the result, and it depends on the components fitted. Seat valves are tight in their closed direction; Römheld describes its ND 4 seat valves as hermetically tight. Spool valves leak, and Wandfluh states that their leakage must be taken into account when designing the system. Rotary couplings and cylinder seals add more. Take leakage values from the component data sheets, or measure them.

Temperature and settling after clamping

Charging the accumulator is fast and close to adiabatic, so the gas heats up; discharge is slow. Römheld notes that as the heated nitrogen cools after clamping, pressure drops and the unit refills once or twice; it advises waiting about 15 seconds until clamping pressure is constant.

A clamping circuit isolated from the pressure source also changes pressure with temperature: Römheld gives roughly ±10 bar per ±1 °C. A small accumulator on the fixture reduces this, and Römheld recommends fitting a pressure gauge in any case.

Shanchuan SC-QT units stop the pump during a hold and restart it when pressure falls below the set level, so the same calculation applies. Hold time for a given machine depends on its accumulator, switch settings and measured leakage; no fixed hold time is claimed.

References

Figures above come from the following public documents. Calculations marked as estimates are derived from them.

Sources

  • Römheld, Hydraulic Accumulators, data sheet F 9.601, pp. 1–3
  • Römheld, Directional Control Valves ND 4, data sheet C 2.320, p. 1
  • Wandfluh, Solenoid operated spool valve NG6, data sheet 1.2-58 E, pp. 1, 4
  • Parker Hannifin, Hydraulic Accumulators, Catalog HY10-1630/US, pp. 130, 136–137
  • HYDAC, Bladder Accumulators – Standard design, brochure EN 3.201.31/04.21, §2.1
  • Danfoss, Hydraulic Fluids and Lubricants, Technical Information 520L0463, p. 11

FAQ

Frequently asked questions

How do I find the leakage rate?

Use the leakage data of the valves, rotary couplings and cylinders fitted, or measure it: isolate the circuit at working pressure, record the pressure drop over time, and convert with the accumulator curve.

Why does pressure drop right after clamping?

The nitrogen heated up during fast charging and contracts as it cools. Römheld expects one or two refills and advises waiting about 15 seconds.

How can hold time be extended?

Reduce leakage, for example with seat valves instead of spool valves, use a larger accumulator, or widen the gap between pump-off and pump-on pressure within the limits of the clamps and accumulator.

ENERGY INTO VALUE

Less idle running. More value.

Make each holding phase count. Stop the motor after motion, then recharge when pressure reaches the set threshold, reducing energy use and heat from continuous idle running.

Save 75% or more in short-motion, long-hold applications. Turn reduced electricity use into lower running costs and get more value from every clamping cycle.

Annual electricity cost savingkWh avoided × electricity tariff
Review the savings potential of your machine →