What a change in noise tells you
Bosch Rexroth’s PGH gear pump manual says a slight increase in noise is normal as the oil warms up. A significant increase, or brief random changes in the sound, may indicate the pump is drawing in air.
The same manual lists changes in speed, temperature, noise or power consumption as signs of wear or damage to the system or pump. Note when the noise started and what else changed at the same time.
Air in the oil
Danfoss notes that air in hydraulic fluid causes higher operating temperatures, increased noise and loss of lubricity. Air typically enters through the suction line when seals and fittings are not tight.
Rexroth adds that if suction lines are too short or the oil level is too low, air can be drawn in by a swirl at the suction pipe. After commissioning, it recommends checking the reservoir for bubbles or foam on the surface.
Common causes to check
Eaton’s PVE19 troubleshooting table lists these probable causes of excessive pump noise
- Low oil level in the reservoir
- Air in the system; check suction lines and fittings for air leaks
- Vacuum at the pump inlet
- Oil too thick, or cold weather
Installation and structure-borne noise
Pump noise values in catalogues are for the pump alone. Rexroth states that installation influences such as piping are not included, and that under unfavourable conditions the sound pressure level at the power unit can be 5–10 dB(A) higher than the pump’s own value.
To stop vibration travelling into the structure, Rexroth advises decoupling all connecting lines from vibration-capable parts such as the reservoir and frame with elastic elements. Motor and pump must be exactly aligned, joined by a coupling that compensates shaft offset, with no radial or axial load on the pump shaft.
Valve chatter
A rattling or buzzing valve can also be the source. Swagelok describes chatter in check and relief valves as rapid opening and closing, caused for example by a valve whose flow capacity does not match the system flow, or by operating with inlet pressure close to the cracking pressure. Left unresolved, chatter can damage valve internals and cause leakage. This guidance is for instrument valves; check the data sheet of the hydraulic valve actually fitted.
A step-by-step check
First check the oil level and look for foam in the reservoir. Then check suction-side seals and fittings for air leaks, and measure the vacuum at the pump inlet with a gauge. Check oil grade and temperature against the pump’s viscosity limits. Finally, check alignment, coupling and how lines and the reservoir are mounted.
Noise only while the pump runs is not the same as noise during a pressure hold. On units that stop the pump during holding, such as Shanchuan SC-QT units, the pump runs only to build or restore pressure, so note in which phase of the cycle the noise appears.
References
Statements above come from the following public documents. Limits for your unit come from the data sheets of the components fitted.
Sources
- Bosch Rexroth, Internal gear pump PGH series 2X, data sheet RE 10223, pp. 13–15
- Bosch Rexroth, Axial piston variable pump A10VSO series 31, data sheet RE 92711, p. 43
- Danfoss, Hydraulic Fluids and Lubricants, Technical Information 520L0463, p. 10
- Eaton (Vickers), PVE19 User Manual, Troubleshooting, Table 3
- Swagelok, Check Relief and Valve Chatter, technical bulletin, June 2014
FAQ
Frequently asked questions
Is some noise increase normal as the unit warms up?
Rexroth says a slight increase is normal as the oil heats. A significant increase, or brief random changes in the sound, may mean the pump is drawing in air.
Why is the unit louder on the machine than the catalogue value?
Catalogue values are for the pump alone. Rexroth notes the installed unit can be 5–10 dB(A) louder under unfavourable conditions, because piping, reservoir and frame also radiate noise.
What should I check first?
Oil level, foam in the reservoir and air leaks on the suction side. These are quick to check and are listed first by pump makers.