What ISO VG means
ISO 3448 sets the viscosity classification for industrial lubricants, including hydraulic fluids; ISO confirmed the 1992 edition as current in 2023. The VG number refers to kinematic viscosity at 40 °C.
Viscosity changes with temperature: it falls as oil warms and rises as it cools. A VG 46 oil is only about 46 mm²/s at 40 °C; at the unit’s real temperature it can be much thinner or thicker.
The trade-off
Danfoss puts it simply: oil must be thin enough to flow through filters, inlet and return lines without too much resistance, but not so thin that lubrication suffers and internal leakage grows.
Start from the pump’s viscosity window
Published limits, examples
- Rexroth A10VSO piston pump: optimum 16–36 mm²/s; permissible 10–400 mm²/s; short-term 7–10 mm²/s for at most 3 minutes at reduced pressure
- Rexroth A10VSO: for VG 46 the permissible range corresponds to roughly +4 °C to +85 °C; 10 mm²/s is reached at about 73 °C with HLP 32 and 85 °C with HLP 46
- Rexroth PGH gear pump: 10–300 mm²/s, starting viscosity up to 2000 mm²/s, fluid temperature −10 to +80 °C for HLP oil
- Römheld workholding valve: ISO VG 10 to 68 admissible, HLP 22 recommended for room temperature 10–40 °C
Matching grade to operating temperature
Rexroth says to choose the fluid so that operating viscosity at operating temperature falls in the optimum range. At 40 °C, a VG 32 oil (about 32 mm²/s) already sits inside the 16–36 mm²/s window of the A10VSO; VG 46 and VG 68 only reach it at higher oil temperatures. Which grade fits therefore depends on the real oil temperature and the pump fitted.
Read the actual temperature points from the viscosity–temperature curve of the oil you use. Danfoss notes that its own charts are for reference only and that actual viscosity should be checked with the oil supplier.
Cold start and viscosity index
Cold, thick oil is a suction risk. For the A10VSO, Rexroth allows a cold start up to 1600 mm²/s, not below −25 °C, for at most 3 minutes without load (≤ 50 bar) and at ≤ 1000 rpm, followed by a limited warm-up phase. The temperature difference between pump and oil should not exceed 25 K.
Danfoss recommends a start-up temperature about 15 °C above the oil’s pour point. A higher viscosity index (VI) means viscosity changes less with temperature, which helps units that start cold and run warm.
References
Figures above come from the following public documents. Use the data sheets of the pump, valves and oil actually used.
Sources
- ISO 3448:1992, Industrial liquid lubricants — ISO viscosity classification (ISO standard page)
- Bosch Rexroth, Axial piston variable pump A10VSO series 31, data sheet RE 92711, pp. 4–5
- Bosch Rexroth, Internal gear pump PGH series 2X, data sheet RE 10223, p. 4
- Römheld, Directional Control Valves ND 4, data sheet C 2.320, p. 1
- Danfoss, Hydraulic Fluids and Lubricants, Technical Information 520L0463, pp. 6–8, 17
FAQ
Frequently asked questions
Is VG 46 always better than VG 32?
No. A thicker oil only helps if the unit runs hot enough to bring it into the pump’s optimum window. In a cooler unit, VG 46 may stay thicker than optimum, especially at start-up.
Can I mix or switch grades?
Check with the oil supplier and the component data sheets first. Switching grade moves the operating viscosity, so confirm it still falls within the limits of the pump and valves fitted.
Why do clamping circuits sometimes use thinner oil?
Some workholding components are designed for it. Römheld, for example, recommends HLP 22 for its ND 4 valves at room temperatures of 10–40 °C.